FAQ's

According to NACE MR0175, can UNS S20910 be used for choke valve stems as well as valve stems?

Can UNS S20910 be used in valve stems and choke valve stems?

This page features a question regarding the use of UNS S20910 in the condition specified in Table A.3 for valve stems and choke valve stems. The answer provided confirms that choke valve stems are also included in Table A.3 since choke valves are considered a type of valve in the Oil & Gas Industry. Therefore, UNS S20910 can be used in both valve stems and choke valve stems.

Understanding NACE MR0175/ISO 15156-3 A.3 Table A.3

This question pertains to NACE MR0175/ISO 15156-3 A.3 Table A.3. The reference cited is ISO 15156 Maintenance Panel Inquiry #2015-06.

Are you experiencing technical challenges that are compromising your project? Contact us now and let us to get your project back on track!

Talk to an expert

Get in touch with us